TRaC have a wide range of shock and vibration testing equipment that can reproduce various conditions.
Vibration capabilities cover random, periodic, low or high frequency vibration. Shock testing can be carried out using one of our vertical-drop shock testing machines or electromagnetic shakers. TRaC also support a dynamic test facility dedicated to tests against requirements for telecoms and radio products.
Vibration Test Capabilities
| | Frequency Range | Maximum Displacement
| Rated Thrust
| Acceleration (Sine Peak)
| Slip Table
|
| Large Electromagnetic Vibration shakers (x3) |
5 to 2000 Hz |
38 mm pk-pk
|
Up to 160 kN (36,000 lbf) Sine and Random |
100g
|
Combo & portable
|
| Medium Electromagnetic Vibration Shakers (x3) |
2 to 3000 Hz |
Various from 12.7 mm to 50 mm pk-pk |
Various up to 89 kN (20,000 lbf) Sine and Random |
100g |
Combo & portable |
Small Electromagnetic Vibration Shakers (x8)
|
5 to 3000 Hz |
Various from 11.4 mm to 50 mm pk-pk
|
Various up to 40 kN (9,000 lbf) Sine
|
60g
|
Combo & portable |
| With prefabricated thermal enclosures vibration testing can be combined with the temperature over the range of -70°C to +170°C. |
|
| Frequency Range
| Payload
| Performance
| Slip Table
|
Hydraulic Vibration Tables (Vertical & Horizontal)
|
1 to 150 Hz |
Up to 2000 kg |
Dependent on payload. Designed to meet the requirements of Data Sheet 25 of NES 1004 (Now DEF STAN 08-123) for Naval Equipment |
Separate Vertical and Horizontal Tables |
With prefabricated thermal enclosures vibration testing can be combined with the temperature over the range of -70°C to +170°C.
|
Shock Test Capabilities
| | Platform Size
| Platform Displacement
| Maximum Shock Level
| Shock Profiles
|
Lansmont Vertical-Drop Shock Machine
|
950mm x 950mm
|
-
|
800g, dependent on duration and pulse
|
Half-Sine, Final Peak Sawtooth
|
AVCO Vertical-Drop Shock Machine
|
406mm x 406mm (16" x 16")
|
-
|
1000g, dependent on duration and pulse
|
Half-Sine, Final Peak Sawtooth
|
Electromagnetic Shakers
|
-
|
50mm pk-pk
|
100g, dependent on duration and pulse
|
Classical Shock, Time-Histories, Shock Response Spectra
|
With prefabricated thermal enclosures shock testing can be combined with the temperature over the range of -70°C to +170°C.
|